No results were found for the filter!
HE-080_082_083 grey Main SHEV button type HE 080 Grey
Electrical manual emergency override switch HE-080 grey The HE 080 grey is a main SHEV-button of electrical line-monitored SHEV systems (SHEV 3, SHEV 6, ESM-T / X, - tested according to DIN EN 12101-9). The board can be replaced as...
HE-081 grey Secondary SHEV button type HE 081 Grey
Electric SHEV emergency button, HE 081 gray Secondary SHEV button of electrical line monitored RWA systems (SHEV 3, SHEV 6, ESM-T / X, - tested to DIN EN 12101/9), with interchangeable board, incl. "On" - button, "To" - button (NO) 24 V,...
HE-080_082_083 grey Main SHEV button type HE 082 grey
Electric SHEV emergency button, HE 082 Grey The HE 082 Gray is a main SHEV button of electrical line-monitored SHEV systems (SHEV 3, SHEV 6, ESM-T / X, - tested according to DIN EN 12101-9), whose board is interchangeable. "UP" button...
HE-086 grey Secondary SHEV button type HE 086 Grey
Electrical manual emergency override switch HE-086 The electrical manual push-button type HE 086 are used as auxiliary control unit in smoke and heat extraction systems, respectively for smoke and fire curtains, and serve for the manual...
HE-086 yellow smoke exhaust system Secondary SHEV button type HE 086 Yellow
Electrical manual emergency override switch HE-086 The electrical manual push-button type HE 086 are used as auxiliary control unit in smoke and heat extraction systems, respectively for smoke and fire curtains, and serve for the manual...
HE-087 orange smoke extraction Main SHEV button type HE 087 Orange
Electrical manual emergency override switch HE-087 The electrical manual push-button type HE 087 are used as main emergency button in smoke and heat extraction systems, respectively for smoke and fire curtains, and serve for the manual...
Handansteuereinrichtung HE-87 für Rauch- und Feuerschutzvorhänge Main SHEV button type HE 087 Yellow
Electrical manual emergency override switch HE-087 The electrical manual push-button type HE 087 are used as main emergency button in smoke and heat extraction systems, respectively for smoke and fire curtains, and serve for the manual...
HE-087 smoke exhaust system grey Main SHEV button type HE 087 Grey
Electrical manual emergency override switch HE-087 The electrical manual push-button type HE 087 are used as main emergency button in smoke and heat extraction systems, respectively for smoke and fire curtains, and serve for the manual...
Smoke detector RM 2860 Optical smoke detector RM 2860
Optical smoke detector, type RM-2860 Optical smoke detector, tripping at 3% smoke (EN 54-7), voltage: 9 - 33 V DC, including mounting base, operating current at 30 V, alarm: 52 mA, operating current at 30 V, rest: 30-50 μA, alarm LED ,...
Photo of the scattered light smoke detector RM-3000 Optical smoke detector RM 3000
Optical smoke detector, type RM-3000 Optical smoke detector, tripping at 3% smoke (EN 54-7), voltage: 9 - 33 V DC, including mounting base, operating current at 30 V, alarm: 20 mA, operating current at 30 V, rest: 100 μA, alarm LED , ABS...
Photo of the thermo detector TH-4860 Thermal maximal detector TH-4860
Thermo detector, type TH 4860 24 volt DC, as a thermal differential maximum detector, alarm triggering at 75 °C, incl. relay socket, in a compact white plastic housing with alarm LED, with VdS approval, test number: G 200060. Only...
Photo of the alarm display S-24 Acoustic alarm indicator S-24-ROT
Acoustic alarm indicator S-24-ROT 10 - 32 Volt DC, 42 - 102 mA, as acoustic signal transmitter, max. 105 dB, alarm triggered by 24 volt control, in compact white or red plastic housing, with VdS approval. Test number: G 201040. Only...