No results were found for the filter!
NEW
Acoustic alarm indicator S-24-ROT
Acoustic alarm indicator S-24-ROT 18 - 28 Volt DC, 5 - 33 mA alarm current, as acoustic signal transmitter, max. 112 dB, alarm triggered by 24 volt control, in compact red plastic housing, with VdS approval. Test number: G 206019. Only...
NEW
Optical alarm indicator BI-24
Optical alarm indicator BI-24 / Flashlight, type BI-24 10 - 60 Volt DC, 80 mA, as optical signal transmitter, alarm triggered by 24 volt control, in compact red plastic housing, with VdS approval. Test number: G 207018. Only flashlights...
Additional module THM-200
additional module for thermostat connection (2 channels) Manufacturer: SIMON PROtec Systems GmbH Type: Additional module THM-200 Article number: ST4 3368
additional module THM-100
additional module for thermostat connection (1 channel) Manufacturer: SIMON PROtec Systems GmbH Type: Additional module THM-100 Article number: ST4 3366
Rain detector RD
Rain detector, type RD Rain detector with built-in electronic evaluation unit for automatically closing the connected leaves in the event of rain, with heated sensor surface from galvanic gold to prevent false tripping in dew, snow or...
wind rain detector WRD
Wind / Rain detector, type WRD Wind / Rain detector with built-in evaluation electronics and built-in time delay, for connection to SHEV and ventilation control systems, with heated sensor surface from galvanic gold to prevent false...
Thermal maximal detector TH-5760
Thermo detector, type TH-5760 24 volt DC, as a thermal differential maximum detector, alarm triggering at 57 °C, incl. relay socket, in a compact white plastic housing with alarm LED, with VdS approval, test number: G 200059. Only...
Optical smoke detector RM 2860
Optical smoke detector, type RM-2860 Optical smoke detector, tripping at 3% smoke (EN 54-7), voltage: 9 - 33 V DC, including mounting base, operating current at 30 V, alarm: 52 mA, operating current at 30 V, rest: 30-50 μA, alarm LED ,...
Optical smoke detector RM 3000
Optical smoke detector, type RM-3000 Optical smoke detector, tripping at 3% smoke (EN 54-7), voltage: 9 - 33 V DC, including mounting base, operating current at 30 V, alarm: 20 mA, operating current at 30 V, rest: 100 μA, alarm LED , ABS...
Main SHEV button HE-082-GREY-BIO
Electical manual override switch - main site HE-082 BIOBASED in grey The electric SHEV emergency switch HE-082 as main site switch in grey is used in smoke and heat extraction systems, typ SHEV and M-SHEV. in the case of fire it can be...
Main SHEV button HE-080-GREY-BIO
Electrical manual emergency override switch -main site HE-080 grey BioBased The electric SHEV emergency switch HE-080 as main site switch in grey is used in smoke and het extraction systems witch type SHEV or M-SHEV. In the case of fire...